Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.unicentro.br:8080/jspui/handle/tede/326
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSoares, Tiago Furlanetto-
dc.creator.Latteshttp://lattes.cnpq.br/6023248515954408por
dc.contributor.advisor1Ganzarolli, Edgard Moreira-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/8163033693671022por
dc.contributor.advisor-co1Quináia, Sueli Pércio-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/3256907601004018por
dc.date.accessioned2016-09-20T12:27:17Z-
dc.date.available2011-05-30-
dc.date.issued2011-02-25-
dc.identifier.citationSOARES, Tiago Furlanetto. Desenvolvimento de um Sistema em Fuxos Automatizado para Determinação de Metais-traço em Matrizes Aquosas - Cádmio como metal teste. 2011. 73 f. Dissertação (Programa de Pós-Graduação em Química - Mestrado) - Universidade Estadual do Centro Oeste, Guarapuava-PR.por
dc.identifier.urihttp://localhost:8080/tede/handle/tede/326-
dc.description.resumoEste trabalho apresenta a proposta de um sistema em fluxos automatizado para enriquecimento de amostras aquosas baseado na extração sólido-líquido. Duas bombas de seringa, impulsionam soluções de amostra, agente complexante (verde de bromocresol 0,01% m/v) e eluente (etanol 95 % v/v) através do sistema de fluxos, contendo basicamente seis válvulas solenóides de três vias (Cole-Parmer - USA), uma minicoluna empacotada com Amberlite XAD16 e um minifunil de amostragem. As seringas e as válvulas foram controladas a partir de um PC-AT386 contendo uma interface paralela (ACL 8111-Adlink) e uma interface serial RS232C. Também foi usada uma interface baseada no CI ULN2803A (SGS-Thomson Microelectronics). O sistema foi otimizado usando-se Cd²+ como metal teste, porém poderá ser empregado para qualquer íon metálico após definição dos parâmetros químicos como: tipo de metal, agente complexante, suporte sólido e eluente. A detecção foi realizada off-line por espectrometria de absorção atômica em chama. Para 10 mL de padrões de Cd²+ na faixa de 50 - 500 μg Lˉ¹ e 200 μL de eluato, obteve-se um fator de enriquecimento de 10,6 vezes com limite de detecção de 15 mgLˉ¹ e velocidade analítica de 5 determinações /hora.por
dc.description.abstractThis work presents a automatic flow system for enrichment of aqueous samples based in solid-liquid extraction. Two syringe pumps, driven solutions of samples, complexation agent (bromocresol green 0.01%), eluent (ethanol), through a flow system, basicaly formed by six three way solenoid valves (Cole-Parmer-USA), one mini-column loaded with Amberlite XAD16 and a sampler mini-funeel. The syringes and valves were controled from a PC - AT386 with a paralel interface (ACL 8111-Adlink) and a serial (RS232C) interface. Also was emploied a interface based in ICULN2803A (SGS-Thomson Microelectronics). The system was optimized for Cd ²+ like test metal, however the proposed system may to be used for any metalic ion after definition of chemical parameter, as like: kind of metal, complexation agent, solid suport and eluent. The detection was performed off-line by flame atomic absorptiom spectrometry. For 10 mL of Cd²+ standards in 50 to 500 μg Lˉ¹ range and 200 μL of eluate was obtained a enrichment factor of 10.6 with a detection limit of 15 μgLˉ¹ and analytical frequency of five determinations/hour.eng
dc.description.provenanceMade available in DSpace on 2016-09-20T12:27:17Z (GMT). No. of bitstreams: 1 DISSERTACAO TIAGO FURLANETTO SOARES.pdf: 804150 bytes, checksum: 4e183b86b879060b16f1cfb378daea83 (MD5) Previous issue date: 2011-02-25eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES-
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://localhost:8080/tede/retrieve/1127/DISSERTACAO%20TIAGO%20FURLANETTO%20SOARES.pdf.jpg*
dc.languageporpor
dc.publisherUNICENTRO - Universidade Estadual do Centro Oestepor
dc.publisher.departmentUnicentro::Departamento de Ciências Exatas e de Tecnologiapor
dc.publisher.countryBRpor
dc.publisher.initialsUNICENTROpor
dc.publisher.programPrograma de Pós-Graduação em Química (Mestrado)por
dc.rightsAcesso Abertopor
dc.subjectPré-concentraçãopor
dc.subjectanálise em fluxopor
dc.subjectAutomação Analiticapor
dc.subjectpreconcentrationeng
dc.subjectflow analysiseng
dc.subjectanalytical automationeng
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::QUIMICApor
dc.titleDesenvolvimento de um Sistema em Fuxos Automatizado para Determinação de Metais-traço em Matrizes Aquosas - Cádmio como metal testepor
dc.title.alternativeDevelopment of a Automatic Flow System for Determination of trace metal in aqueous Matrices - Cadmium as a metal testeng
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Química Aplicada

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DISSERTACAO TIAGO FURLANETTO SOARES.pdf785,3 kBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.