Campo DCValorIdioma
dc.creatorMiranda, Luciane-
dc.creator.Latteshttp://lattes.cnpq.br/6282044266923769por
dc.contributor.advisor1Quináia, Sueli Pércio-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3256907601004018por
dc.contributor.advisor-co1Galli, Andressa-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/7322793381463165por
dc.date.accessioned2016-09-20T12:27:10Z-
dc.date.available2015-07-20-
dc.date.issued2012-01-01-
dc.identifier.citationMIRANDA, Luciane. OTIMIZAÇÃO DE UMA METODOLOGIA ELETROANALÍTICA PARA DETERMINAR METILTESTOSTERONA EM AMOSTRAS AMBIENTAIS. 2012. 89 f. Dissertação (Programa de Pós-Graduação em Química - Mestrado) - Universidade Estadual do Centro Oeste, Guarapuava, 2012.por
dc.identifier.urihttp://localhost:8080/tede/handle/tede/286-
dc.description.resumoNeste trabalho descreve-se o desenvolvimento uma metodologia eletroanalítica para a determinação do hormônio 17α-metiltestosterona em amostras ambientais, empregando o eletrodo de gota pendente de mercúrio (HMDE). Inicialmente, foram realizados estudos por voltametria cíclica, quais mostraram que o 17α-etiltestosterona possui apenas um pico de redução em -1,35 V vs Ag/AgCl, em meio de KCl (3,0 mol Lˉ¹), com características irreversíveis e processo controlado pela adsorção das espécies na superfície do eletrodo. Parâmetros como eletrólito suporte, concentração hidrogeniônica do meio bem como, os parâmetros da técnica de voltametria de onda quadrada (SWV) como frequência de aplicação de pulsos de potencial (ƒ), amplitude dos pulsos de potencial (a) e incremento de varredura (∆Es) foram avaliados e otimizados. Estabelecidas as melhores condições, curvas de trabalho por meio do método de adição padrão de 17α-metiltestosterona, foram obtidas e os limites de detecção (LD) e de quantificação (LQ) calculados foram de 3,07 μg Lˉ¹ e 10,78 μg Lˉ¹, respectivamente. A metodologia otimizada para o hormônio 17α-metiltestosterona foi aplicada em águas ultrapura e naturais para avaliar recuperação e quantificar o analito nessas matrizes. As curvas de recuperação obtidas pela técnica de adição de padrão, possibilitaram determinar quantidades adicionadas em amostras fortificadas. Os valores de recuperação de 17α-metiltestosterona em água ultrapura foram de 100,38 % e, em águas naturais de 108,79 % e 115, 0 %. Efeitos de interferência de matriz foram observados em amostras reais e, com a diluíção das amostras este efeito foi minimizado, permitindo boas recuperações ao nível de análise de traços. O analito foi quantificado em amostras de tanques de peixe em valores de até 228,7 μg Lˉ¹ O estudo de repetibilidade apresentou coeficiente de variação (CV) de 2,85 % e a reprodutibilidade o CV de 14,91 %, estes valores se mostraram adequados para análises de traçospor
dc.description.abstractThis work describes the development of an electroanalytical methodology for determining the hormone 17α-methyltestosterone in environmental samples, using the electrode hanging mercury drop (HMDE). Initially, studies were performed by cyclic voltammetry, which showed that 17α-methyltestosterone, has only a reduction peak at -1.35 V vs. Ag/AgCl,(in KCl 3.0 mol Lˉ¹), with features irreversible process and controlled by adsorption of species on the electrode surface. Parameters such as supporting electrolyte, hydrogen ion concentration of the medium, as well as, the parameters of the technique of square wave voltammetry (SWV) and frequency of application of potential pulses (ƒ), amplitude of pulses of potential (a) and scan increment (∆Es) were evaluated. Established the best conditions, working curves by the method of standard addition of 17α-methyltestosterone were obtained and the limits of detection (LOD) and quantification (LOQ) values were 3.07 μg Lˉ¹ and 10.78 μg Lˉ¹, respectively. The optimized methodology for the 17α-methyltestosterone was applied in purified water and natural to evaluate the presence of 17α-methyltestosterone in these matrices. The recovery curves obtained by standard addition technique, it was possible to determine amounts of 17α-methyltestosterone added in spiked samples. The recovering in purified water were 100.38%, and natural waters from 108.79% to 115.0%. The effects of matrices Interference were observed in natural water and with dilution of sample this effect was eliminated, allowing good recoveries at the level of trace analysis. The compound was quantified in samples of fish ponds in amounts up to 206.9 mg Lˉ¹. The study showed repeatability coefficient of variation (CV) of 2.85% and reproducibility CV of 14.91%, adequate in analysis of traces.eng
dc.description.provenanceMade available in DSpace on 2016-09-20T12:27:10Z (GMT). No. of bitstreams: 1 PR LUCIANE MIRANDA.pdf: 1274520 bytes, checksum: 6a8cc6db4149de9162b282fd4eb06bcb (MD5) Previous issue date: 2012-01-01eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES-
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://localhost:8080/tede/retrieve/1047/PR%20LUCIANE%20MIRANDA.pdf.jpg*
dc.languageporpor
dc.publisherUNICENTRO - Universidade Estadual do Centro Oestepor
dc.publisher.departmentUnicentro::Departamento de Ciências Exatas e de Tecnologiapor
dc.publisher.countryBRpor
dc.publisher.initialsUNICENTROpor
dc.publisher.programPrograma de Pós-Graduação em Química (Mestrado)por
dc.rightsAcesso Abertopor
dc.subject17α-metiltestosterona, voltametria de onda quadrada, eletrodo de gota pendente de mercúriopor
dc.subject17α-methyltestosteroneeng
dc.subjectsquare wave voltametryeng
dc.subjecthanging mercury drop electrodeeng
dc.subject.cnpqCIENCIAS EXATAS E DA TERRA::QUIMICApor
dc.titleOTIMIZAÇÃO DE UMA METODOLOGIA ELETROANALÍTICA PARA DETERMINAR METILTESTOSTERONA EM AMOSTRAS AMBIENTAISpor
dc.title.alternativenão constaeng
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Química Aplicada

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
PR LUCIANE MIRANDA.pdf1,24 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar