Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.unicentro.br:8080/jspui/handle/jspui/880
Registro completo de metadados
Campo DCValorIdioma
dc.creatorFILIPAKI, ANDRESSA-
dc.creator.Latteshttp://lattes.cnpq.br/9096805566294098por
dc.contributor.advisor1Vidal, Carlos Magno de Sousa-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1554298849674091por
dc.contributor.advisor-co1Souza, Jeanette Beber de-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/3539413296260672por
dc.date.accessioned2018-07-31T13:36:15Z-
dc.date.issued2018-03-16-
dc.identifier.citationFILIPAKI, ANDRESSA. ESTUDO DA TRATABILIDADE DE ÁGUA DE LAVAGEM DE FILTRO EMPREGANDO COAGULANTE RECUPERADO DE LODO DECANTADOR. 2018. 88f. Dissertação (Programa de Pós-Graduação em Engenharia Sanitária e Ambiental - Mestrado / Associação Ampla com UEPG) - Universidade Estadual do Centro-Oeste, Irati - PR.por
dc.identifier.urihttp://tede.unicentro.br:8080/jspui/handle/jspui/880-
dc.description.resumoEste estudo teve por objetivo investigar a sedimentabilidade da água de lavagem dos filtros de uma estação de tratamento de água com e sem o uso de coagulante recuperado a partir do lodo do decantador. O trabalho experimental consistiu na recuperação do coagulante (cloreto de polialumínio) pela via ácida, em que foi possível obter uma concentração de 793,7 mg.L-1 de Al, que aplicado nos ensaios de coagulação, floculação e sedimentação da água de lavagem dos filtros permitiu a redução da turbidez para valores entre 1,4 e 3,6 uT. Nos ensaios em coluna de sedimentação sem a adição de coagulantes, em 120 minutos observaram-se condições semelhantes aos ensaios de coagulação com valores de turbidez remanescente variando entre 1,9 e 9,0 uT. A avaliação microbiológica da água de lavagem dos filtros após a clarificação foi testada para as bactérias indicadoras Escherichia coli, coliformes totais e Clostridium perfringens. A clarificação nos ensaios de coagulação apresentou maior redução na concentração remanescente de microrganismos em comparação à sedimentação sem o uso de condicionantes químicos. Posteriormente, a água de lavagem clarificada foi submetida a ensaios de desinfecção com o uso da radiação ultravioleta. Nas doses empregadas neste estudo, a Escherichia coli apresentou menor resistência à desinfecção, seguida de Clostridium perfringens e coliformes totais.por
dc.description.abstractThe objective of this study was to investigate the sedimentability of the filter backwash water from the a water treatment plant with and without the use of coagulant recovered from the decanter sludge. The experimental work consisted in the recovery of the coagulant (polyaluminium chloride) by the acid path, in which it was possible to obtain a concentration of 793.7 mg.L-1 of Al, which applied to the coagulation, flocculation and sedimentation of wash water from the filters allowed to reduced turbidity to values between 1.4 and 3.6 uT. In the tests in sedimentation column without the addition of coagulants, in 120 minutes they reached similar conditions to the coagulation tests with remaining turbidity values ranging from 1.9 to 9.0 uT. The microbiological evaluation of the wash water of the filters after clarification was tested for the indicator bacteria Escherichia coli, total coliforms and Clostridium perfringens. The clarification in the coagulation tests presented a greater reduction in the remaining concentration of microorganisms in comparison to the sedimentation without the use of chemical conditioners. Afterwards, the clarified washing water was submitted to disinfection tests with the use of ultraviolet radiation. With the doses used in this study, Escherichia coli showed less resistance to disinfection, followed by the Clostridium perfringens and total coliforms.eng
dc.description.provenanceSubmitted by Fabiano Jucá (fjuca@unicentro.br) on 2018-07-31T13:36:15Z No. of bitstreams: 1 Andressa Filipaki.pdf: 2050492 bytes, checksum: 2bcac7d27650d873c3112485acff4191 (MD5)eng
dc.description.provenanceMade available in DSpace on 2018-07-31T13:36:15Z (GMT). No. of bitstreams: 1 Andressa Filipaki.pdf: 2050492 bytes, checksum: 2bcac7d27650d873c3112485acff4191 (MD5) Previous issue date: 2018-03-16eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede.unicentro.br:8080/jspui/retrieve/3876/Andressa%20Filipaki.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Estadual do Centro-Oestepor
dc.publisher.departmentUnicentro::Departamento de Ciências Agrárias e Ambientaispor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNICENTROpor
dc.publisher.programPrograma de Pós-Graduação em Engenharia Sanitária e Ambiental (Mestrado / Associação Ampla com UEPG)por
dc.rightsAcesso Abertopor
dc.subjectresíduos do tratamento de águapor
dc.subjectindicadores de contaminação fecalpor
dc.subjectdesinfecção UVpor
dc.subjectrecuperação de coagulantepor
dc.subjectágua de lavagem do filtropor
dc.subjectwater treatment residualseng
dc.subjectfaecal indicator organismeng
dc.subjectUV disinfectioneng
dc.subjectcoagulant recoveryeng
dc.subjectfilter backwash watereng
dc.subject.cnpqENGENHARIASpor
dc.subject.cnpqENGENHARIAS::ENGENHARIA SANITARIApor
dc.titleESTUDO DA TRATABILIDADE DE ÁGUA DE LAVAGEM DE FILTRO EMPREGANDO COAGULANTE RECUPERADO DE LODO DECANTADORpor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Engenharia Sanitária e Ambiental (Associação com Universidade Estadual de Ponta Grossa)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Andressa Filipaki.pdfANDRESSA FILIPAKI2 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.