dc.identifier.citationFERREIRA, ALINE TROG. AVALIAÇÃO DO EMPREGO DA RADIAÇÃO ULTRAVIOLETA NA DESINFECÇÃO DE ÁGUA DE LAVAGEM DE FILTRO DE ESTAÇÃO DE TRATAMENTO DE ÁGUA. 2022. 66 f. Dissertação (Programa de Pós-Graduação em Engenharia Sanitária e Ambiental - Mestrado / Associação Ampla com UEPG) - Universidade Estadual do Centro-Oeste, Irati-PR.por
dc.identifier.urihttp://tede.unicentro.br:8080/jspui/handle/jspui/1984-
dc.description.resumoA lavagem dos filtros em uma estação de tratamento de água (ETA) convencional pode representar o consumo de 3 a 10% da produção total de água tratada. Como esse volume é elevado, existe potencial interesse na sua recirculação. No entanto, existem algumas precauções que devem ser tomadas, pois essa água residuária pode conter metais, matéria orgânica, sólidos, precursores de trihalometanos, cistos e oocistos de protozoários, indicadores de contaminação fecal ou outras impurezas que permanecem no processo de filtração. Esta pesquisa teve como objetivo investigar os processos de coagulação, floculação e decantação com e sem o uso do coagulante químico sulfato de alumínio, aplicado a água de lavagem de filtro de uma ETA convencional e sua posterior desinfecção com radiação ultravioleta. Na realização dos ensaios utilizou-se um equipamento jar-test e um reator UV em escala de bancada. Os resultados demonstraram que sem o emprego de coagulante químico (0 mg.L−1) e com 30 minutos de decantação o valor médio de turbidez foi reduzido para 4,92 uT, promovendo o melhor valor de remoção. A avaliação dos microrganismos E. coli, coliformes totais e esporos de bactérias aeróbias foi realizada após o tratamento preliminar da água de lavagem em equipamento jar-test com três ensaios e uma altura de lâmina líquida de 2 cm, o tratamento estatístico dos dados foi realizado por meio do teste de Tukey. Para os ensaios com radiação UV, após a aplicação de doses que variaram de 200,42 mWs.cm−2 a 721,53 mWs.cm−2, observou-se que a remoção média de E. coli foi de 1,5 logs, e após análise de variância observou-se que não houve diferença significativa entre as médias, com o aumento das doses de radiação UV empregadas em todos os ensaios. Para coliformes totais, ocorreram decréscimos significativos na remoção, alcançando remoção média de 3,21 logs de inativação. O grupo esporos de bactérias aeróbias não apresentou maior resistência à radiação UV em todos os ensaios, e não houve diferença significativa entre as médias, alcançando eficiência de inativação média de 3,92 logs. Desta forma, o estudo permitiu consolidar a boa perspectiva da aplicação da coagulação, floculação, decantação, seguida da radiação UV como alternativa de tratamento de água de lavagem de filtro de estação de tratamento de água, permitindo uma melhor qualidade na água residuária e recirculação de forma mais segura.por
dc.description.abstractThe backwash water in a conventional water treatment plant (WTP) can represent 3 to 10% of the total production of treated water. As this volume is high, there is potential interest in the recirculation of this waste. However, there are some precautions that should be taken, as this wastewater may contain metals, organic matter, solids, trihalomethanes precursors, cysts and oocysts protozoan, indicators of fecal contamination, or other impurities that remain in the filtration process. This research aimed to investigate the process of coagulation, flocculation, and decantation with and without the use of chemical coagulant aluminum sulfate applied to the filter backwash water of a conventional WTP and its subsequent disinfection with ultraviolet radiation. During the tests, the equipment used was a jar-test and a bench-scale UV reactor. Without using a chemical coagulant (0 mg.L−1) and with 30 minutes of decantation, the average turbidity value was reduced to 4.92 uT, promoting the best removal value. The evaluation of microorganisms E. coli, total coliforms and spores of aerobic bacteria were performed after the preliminary treatment of the washing water in jar-test equipment with three assays and a liquid depth of 2 cm, the statistical treatment of the data was performed using the Tukey test. For the tests with UV radiation, after the application of doses that varied from 200.42 mWs.cm−2 to 721.53 mWs.cm−2, it was observed that the average removal from E. coli was 1.5 logs, and after analysis of variance, it was observed that there was no significant difference between the means, with increasing doses of UV radiation used in all tests. For total coliforms, there were significant decreases in removal, reaching an average removal of 3.21 logs of inactivation. The aerobic bacteria spores group did not show greater resistance to UV radiation in all tests, and there was no significant difference between the means, reaching an average inactivation efficiency of 3.92 logs. In this way, the study allows the consolidation of the good perspective of the application of coagulation, flocculation, and decantation, followed by UV radiation as an alternative in the treatment of filter backwash water, allowing for better water quality waste and recirculation more safely.eng
dc.description.provenanceSubmitted by Fabiano Jucá (fjuca@unicentro.br) on 2022-12-08T18:14:57Z No. of bitstreams: 1 Dissertação - Aline Trog Ferreira.pdf: 3008179 bytes, checksum: 345696dbe37993a260c1c69810ca00b3 (MD5)eng
dc.description.provenanceMade available in DSpace on 2022-12-08T18:14:57Z (GMT). No. of bitstreams: 1 Dissertação - Aline Trog Ferreira.pdf: 3008179 bytes, checksum: 345696dbe37993a260c1c69810ca00b3 (MD5) Previous issue date: 2022-12-06eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede.unicentro.br:8080/jspui/retrieve/8586/Disserta%c3%a7%c3%a3o%20-%20Aline%20Trog%20Ferreira.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Estadual do Centro-Oestepor
dc.publisher.departmentUnicentro::Departamento de Ciências Agrárias e Ambientaispor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNICENTROpor
dc.publisher.programPrograma de Pós-Graduação em Engenharia Sanitária e Ambiental (Mestrado / Associação Ampla com UEPG)por
dc.rightsAcesso Abertopor
dc.subjectReator Ultravioletapor
dc.subjectInativaçãopor
dc.subjectMicrorganismospor
dc.subjectEscherichia colipor
dc.subjectEsporos de Bactérias Aeróbiaspor
dc.subjectUltraviolet Reactoreng
dc.subjectInactivationeng
dc.subjectMicroorganismseng
dc.subjectEscherichia colieng
dc.subjectAerobic Bacteria Sporeseng
dc.subject.cnpqENGENHARIASpor
dc.subject.cnpqENGENHARIAS::ENGENHARIA SANITARIApor
dc.titleAVALIAÇÃO DO EMPREGO DA RADIAÇÃO ULTRAVIOLETA NA DESINFECÇÃO DE ÁGUA DE LAVAGEM DE FILTRO DE ESTAÇÃO DE TRATAMENTO DE ÁGUApor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Engenharia Sanitária e Ambiental (Associação com Universidade Estadual de Ponta Grossa)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Dissertação - Aline Trog Ferreira.pdfDissertação - Aline Trog Ferreira2,94 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.